Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71.158
Filtrar
1.
J Morphol ; 285(5): e21695, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38695520

RESUMEN

Artiodactyls exhibit a striking diversity of the cervical vertebral column in terms of length and overall mobility. Using finite element analysis, this study explores the morphology at the cervico-thoracic boundary and its performance under loads in artiodactyls with different habitual neck postures and body sizes. The first thoracic vertebra of 36 species was loaded with (i) a compressive load on the vertebral body to model the weight of the head and neck exerted onto the trunk; and (ii) a tensile load at the spinous process to model the pull via the nuchal ligament. Additional focus was laid on the peculiar shape of the first thoracic vertebra in giraffes. We hypothesized that a habitually upright neck posture should be reflected in the greater ability to withstand compressive loads compared to tensile loads, whereas for species with a habitually suspended posture it should be the opposite. In comparison to species with a suspended posture, species with an upright posture exhibited lower stress (except Giraffidae). For compressive loads in larger species, stress surprisingly increased. Tensile loads in larger species resulted in decreased stress only in species with an intermediate or suspensory neck posture. High stress under tensile loads was mainly reflecting the relative length of the spinous process, while high stress under compressive loads was common in more "bell"-shaped vertebral bodies. The data supports a stability-mobility trade-off at the cervico-thoracic transition in giraffes. Performance under load at the cervico-thoracic boundary is indicative of habitual neck posture and is influenced by body size.


Asunto(s)
Artiodáctilos , Análisis de Elementos Finitos , Vértebras Torácicas , Animales , Vértebras Torácicas/fisiología , Vértebras Torácicas/anatomía & histología , Artiodáctilos/anatomía & histología , Artiodáctilos/fisiología , Postura/fisiología , Fenómenos Biomecánicos , Estrés Mecánico , Soporte de Peso/fisiología
2.
BMC Oral Health ; 24(1): 546, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38730400

RESUMEN

BACKGROUND: Recently, a new generation of high-strength flowable dental composites has been introduced by manufacturers. The manufacturers claim that these materials have enhanced mechanical and physical properties and are suitable for use in a wide range of direct anterior and posterior restorations, even in high-stress bearing areas. AIM: The objective of this study was to assess certain physical and mechanical properties of these recently introduced high-strength flowable composites in comparison to conventional multipurpose dental composites. METHODS: Four types of high-strength flowable composites (Genial Universal FLO, Gaenial Universal Injectable, Beautifil Injectable, and Beautifil Flow Plus) were tested in experimental groups, while a nanohybrid conventional composite (Filtek Z350 XT) was used as the control. For flexure properties, ten rectangular samples (2 × 2 × 25 mm) were prepared from each composite material and subjected to 5000 cycles of thermocycling. Samples were then subjected to flexural strength testing using the universal testing machine. Another twenty disc-shaped specimens of dimensions (5 mm diameter × 2 mm thickness) were fabricated from each composite material for surface roughness (Ra) (n = 10) and hardness (VHN) test (n = 10). All samples underwent 5000 cycles of thermocycling before testing. Additionally, microleakage testing was conducted on 60 standardized class V cavities prepared on molar teeth and divided randomly into five groups (n = 12). Cavities were then filled with composite according to the manufacturer's instructions and subjected to thermocycling for 1000 cycles before testing using methylene blue solution and a stereomicroscope. RESULTS: All tested materials were comparable to the control group in terms of flexural strength and surface roughness (p > 0.05), with Gaenial Universal FLO exhibiting significantly higher flexural strength compared to the other flowable composite materials tested. However, all tested materials demonstrated significantly lower elastic modulus and surface hardness than the control group (p < 0.05). The control group exhibited higher microleakage scores, while the lowest scores were observed in the Gaenial Universal FLO material (p < 0.05) CONCLUSION: The physical and mechanical behaviors of the different high-strength flowable composites investigated in this study varied. Some of these materials may serve as suitable alternatives to conventional composites in specific applications, emphasizing the importance of dentists being familiar with material properties before making material selections.


Asunto(s)
Resinas Compuestas , Filtración Dental , Resistencia Flexional , Dureza , Ensayo de Materiales , Propiedades de Superficie , Técnicas In Vitro , Humanos , Análisis del Estrés Dental , Materiales Dentales/química , Estrés Mecánico , Polietilenglicoles , Ácidos Polimetacrílicos/química , Bisfenol A Glicidil Metacrilato
3.
Int J Biol Sci ; 20(7): 2727-2747, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38725857

RESUMEN

Phenotypic switching (from contractile to synthetic) of vascular smooth muscle cells (VSMCs) is essential in the progression of atherosclerosis. The damaged endothelium in the atherosclerotic artery exposes VSMCs to increased interstitial fluid shear stress (IFSS). However, the precise mechanisms by which increased IFSS influences VSMCs phenotypic switching are unrevealed. Here, we employed advanced numerical simulations to calculate IFSS values accurately based on parameters acquired from patient samples. We then carefully investigated the phenotypic switching and extracellular vesicles (EVs) secretion of VSMCs under various IFSS conditions. By employing a comprehensive set of approaches, we found that VSMCs exhibited synthetic phenotype upon atherosclerotic IFSS. This synthetic phenotype is the upstream regulator for the enhanced secretion of pro-calcified EVs. Mechanistically, as a mechanotransducer, the epidermal growth factor receptor (EGFR) initiates the flow-based mechanical cues to MAPK signaling pathway, facilitating the nuclear accumulation of the transcription factor krüppel-like factor 5 (KLF5). Furthermore, pharmacological inhibiting either EGFR or MAPK signaling pathway blocks the nuclear accumulation of KLF5 and finally results in the maintenance of contractile VSMCs even under increased IFSS stimulation. Collectively, targeting this signaling pathway holds potential as a novel therapeutic strategy to inhibit VSMCs phenotypic switching and mitigate the progression of atherosclerosis.


Asunto(s)
Receptores ErbB , Vesículas Extracelulares , Factores de Transcripción de Tipo Kruppel , Músculo Liso Vascular , Miocitos del Músculo Liso , Estrés Mecánico , Vesículas Extracelulares/metabolismo , Receptores ErbB/metabolismo , Factores de Transcripción de Tipo Kruppel/metabolismo , Factores de Transcripción de Tipo Kruppel/genética , Humanos , Músculo Liso Vascular/metabolismo , Miocitos del Músculo Liso/metabolismo , Líquido Extracelular/metabolismo , Fenotipo , Animales , Aterosclerosis/metabolismo , Sistema de Señalización de MAP Quinasas , Transducción de Señal
4.
Dis Model Mech ; 17(4)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38691000

RESUMEN

Mechanical stimulation as a mimic of drusen formation in the eye increases the expression of angiogenic factors in retinal pigment epithelial (RPE) cells, but the underlying molecular mechanisms remain unclear. We investigated and characterized the effects of mechanical stimulation on the expression of angiogenic factors in RPE cells both in vitro and in a mouse model. Mechanical stimulation increased the expression of vascular endothelial growth factor (VEGF, encoded by VEGFA) and other angiogenesis-related genes in cultured RPE1 cells. The presence of hypoxia-inducible factor 1α (HIF-1α, encoded by HIF1A) was also increased, and both knockdown of HIF-1α and treatment with the HIF-1α inhibitor CAY10585 attenuated the effect of mechanical stimulation on angiogenesis factor gene expression. Signaling by the tyrosine kinase SRC and p38 mitogen-activated protein kinase was involved in HIF-1α activation and consequent angiogenesis-related gene expression induced by mechanical stimulation. Our results suggest that SRC-p38 and HIF-1α signaling are involved in the upregulation of angiogenic factors in RPE cells by mechanical stimulation. Such in vivo suppression of upregulated expression of angiogenesis-related genes by pharmacological inhibitors of HIF-1α suggests a new potential approach to the treatment of age-related macular degeneration.


Asunto(s)
Subunidad alfa del Factor 1 Inducible por Hipoxia , Ratones Endogámicos C57BL , Epitelio Pigmentado de la Retina , Regulación hacia Arriba , Proteínas Quinasas p38 Activadas por Mitógenos , Familia-src Quinasas , Epitelio Pigmentado de la Retina/metabolismo , Subunidad alfa del Factor 1 Inducible por Hipoxia/metabolismo , Animales , Proteínas Quinasas p38 Activadas por Mitógenos/metabolismo , Familia-src Quinasas/metabolismo , Factor A de Crecimiento Endotelial Vascular/metabolismo , Estrés Mecánico , Transducción de Señal , Ratones , Línea Celular , Inductores de la Angiogénesis/metabolismo , Células Epiteliales/metabolismo , Humanos
5.
J Orthop Surg (Hong Kong) ; 32(2): 10225536241251926, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38733065

RESUMEN

AIM: To explore the effects of tibial osteotomy varus angle combined with posterior tibial slope (PTS) on the stress of polyethylene liner in total knee arthroplasty (TKA) by building finite element model (FEM). METHODS: Established the FEM of standard TKA with tibial osteotomy varus angle 0° to 9° were established and divided into 10 groups. Next, each group was created 10 FEMs with 0° to 9° PTS separately. Calculated the stress on polyethylene liner in each group in Abaqus. Finally, the relevancy between tibial osteotomy angle and polyethylene liner stress was statistically analyzed using multiple regression analysis. RESULTS: As the varus angle increased, the area of maximum stress gradually shifted medially on the polyethylene liner. As the PTS increases, the percentage of surface contact forces on the medial and lateral compartmental of the polyethylene liner gradually converge to the same. When the varus angle is between 0° and 3°, the maximum stress of the medial compartmental surfaces of polyethylene liner rises smoothly with the increase of the PTS. When the varus angle is between 4° and 9°, as the increase of the PTS, the maximum stress of polyethylene liner rises first and then falls, forming a trough at PTS 5° and then rises again. Compared to the PTS, the varus angle has a large effect on the maximum stress of the polyethylene liner (p < .001). CONCLUSION: When the varus angle is 0° to 3°, PTS 0° is recommended, which will result in a more equalized stress distribution of the polyethylene liner in TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Análisis de Elementos Finitos , Prótesis de la Rodilla , Osteotomía , Polietileno , Estrés Mecánico , Tibia , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Osteotomía/métodos , Tibia/cirugía , Diseño de Prótesis
6.
Sci Rep ; 14(1): 10808, 2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38734763

RESUMEN

Finite element analysis (FEA) is commonly used in orthopaedic research to estimate localised tissue stresses and strains. A variety of boundary conditions have been proposed for isolated femur analysis, but it remains unclear how these assumed constraints influence FEA predictions of bone biomechanics. This study compared the femoral head deflection (FHD), stresses, and strains elicited under four commonly used boundary conditions (fixed knee, mid-shaft constraint, springs, and isostatic methods) and benchmarked these mechanics against the gold standard inertia relief method for normal and pathological femurs (extreme anteversion and retroversion, coxa vara, and coxa valga). Simulations were performed for the stance phase of walking with the applied femoral loading determined from patient-specific neuromusculoskeletal models. Due to unrealistic biomechanics observed for the commonly used boundary conditions, we propose a novel biomechanical constraint method to generate physiological femur biomechanics. The biomechanical method yielded FHD (< 1 mm), strains (approaching 1000 µÎµ), and stresses (< 60 MPa), which were consistent with physiological observations and similar to predictions from the inertia relief method (average coefficient of determination = 0.97, average normalized root mean square error = 0.17). Our results highlight the superior performance of the biomechanical method compared to current methods of constraint for  both healthy and pathological femurs.


Asunto(s)
Fémur , Análisis de Elementos Finitos , Marcha , Estrés Mecánico , Humanos , Fémur/fisiología , Marcha/fisiología , Fenómenos Biomecánicos , Masculino , Adulto , Simulación por Computador , Femenino
7.
PLoS One ; 19(5): e0297994, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38696455

RESUMEN

When using end shield shearer to recover end slope coal resources, the stability of the overlying rock slope of the end slope is controlled by leaving coal pillars. Due to the influence of the self weight of the overlying rock layer, the coal pillar will be subjected to eccentric loads, and the influence of eccentric loads needs to be considered in the design of the coal pillar size. With the help of PFC discrete element software, uniaxial compression tests were carried out on coal sample containing hole defects under different degrees of eccentric loads based on the calibration of micro mechanical parameters. The results show that the peak stress, cracking stress and dilatancy stress of coal sample decrease in a linear function law with the increase of load eccentricity coefficient. The evolution of the number of microscopic cracks during uniaxial compression under eccentric load can be divided into four stages: the calm stage before crack initiation I, the stable propagation stage II, the unstable propagation and penetration stage III, and the post failure stage IV. The distribution of macroscopic cracks is jointly influenced by the relative position of the loading area and the hole defect. When the hole defect is within the loading area, the hole plays a guiding role in the evolution of coal sample cracks, and the macroscopic crack runs through the edge of the loading area and the hole. When the hole defect is located outside the loading zone, the degree of eccentric load is large, weakening the guiding effect of the hole defect on the crack, and the macroscopic crack does not pass through the hole defect.


Asunto(s)
Carbón Mineral , Estrés Mecánico , Fuerza Compresiva
8.
Int J Mol Sci ; 25(9)2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38732241

RESUMEN

Biodegradable (BP) poly(D,L-lactic acid) (PDLLA) membranes are widely used in tissue engineering. Here, we investigate the effects of varying concentrations of PDLLA/gelatin membranes electrospun in 1,1,1,3,3,3-hexafluoro-2-propanol (HFIP; C3H2F6O) solvent on their mechanical and physical properties as well as their biocompatibility. Regardless of the environmental conditions, increasing the gelatin content resulted in elevated stress and reduced strain at membrane failure. There was a remarkable difference in strain-to-failure between dry and wet PDLLA/gelatin membranes, with wet strains consistently higher than those of the dry membranes because of the hydrophilic nature of gelatin. A similar wet strain (εw = 2.7-3.0) was observed in PDLLA/gelatin membranes with a gelatin content between 10 and 40%. Both dry and wet stresses increased with increasing gelatin content. The dry stress on PDLLA/gelatin membranes (σd = 6.7-9.7 MPa) consistently exceeded the wet stress (σw = 4.5-8.6 MPa). The water uptake capacity (WUC) improved, increasing from 57% to 624% with the addition of 40% gelatin to PDLLA. PDLLA/gelatin hybrid membranes containing 10 to 20 wt% gelatin exhibited favorable wet mechanical properties (σw = 5.4-6.3 MPa; εw = 2.9-3.0); WUC (337-571%), degradability (11.4-20.2%), and excellent biocompatibility.


Asunto(s)
Gelatina , Membranas Artificiales , Poliésteres , Gelatina/química , Poliésteres/química , Materiales Biocompatibles/química , Ensayo de Materiales , Ingeniería de Tejidos/métodos , Agua/química , Estrés Mecánico , Humanos
9.
Medicine (Baltimore) ; 103(19): e38065, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38728521

RESUMEN

Knee varus (KV) deformity leads to abnormal forces in the different compartments of the joint cavity and abnormal mechanical loading thus leading to knee osteoarthritis (KOA). This study used computer-aided design to create 3-dimensional simulation models of KOA with varying varus angles to analyze stress distribution within the knee joint cavity using finite element analysis for different varus KOA models and to compare intra-articular loads among these models. Additionally, we developed a cartilage loading model of static KV deformity to correlate with dynamic clinical cases of cartilage injury. Different KV angle models were accurately simulated with computer-aided design, and the KV angles were divided into (0°, 3°, 6°, 9°, 12°, 15°, and 18°) 7 knee models, and then processed with finite element software, and the Von-Mises stress distribution and peak values of the cartilage of the femoral condyles, medial tibial plateau, and lateral plateau were obtained by simulating the human body weight in axial loading while performing the static extension position. Finally, intraoperative endoscopy visualization of cartilage injuries in clinical cases corresponding to KV deformity subgroups was combined to find cartilage loading and injury correlations. With increasing varus angle, there was a significant increase in lower limb mechanical axial inward excursion and peak Von-Mises stress in the medial interstitial compartment. Analysis of patients' clinical data demonstrated a significant correlation between varus deformity angle and cartilage damage in the knee, medial plateau, and patellofemoral intercompartment. Larger varus deformity angles could be associated with higher medial cartilage stress loads and increased cartilage damage in the corresponding peak stress area. When the varus angle exceeds 6°, there is an increased risk of cartilage damage, emphasizing the importance of early surgical correction to prevent further deformity and restore knee function.


Asunto(s)
Cartílago Articular , Análisis de Elementos Finitos , Articulación de la Rodilla , Osteoartritis de la Rodilla , Humanos , Osteoartritis de la Rodilla/fisiopatología , Osteoartritis de la Rodilla/cirugía , Cartílago Articular/diagnóstico por imagen , Cartílago Articular/patología , Articulación de la Rodilla/fisiopatología , Masculino , Soporte de Peso/fisiología , Fenómenos Biomecánicos , Persona de Mediana Edad , Estrés Mecánico , Femenino , Simulación por Computador , Anciano
10.
Cell Metab ; 36(5): 888-890, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38718755

RESUMEN

Bone is an endocrine organ that participates in whole-body homeostasis. The biology of bone-derived osteokines, however, remains unclear. Liang et al. integrate experimental and computational methods to discover new osteokines, establish their cell of origin and target site, and study their role in aging and during mechanical stress.


Asunto(s)
Huesos , Humanos , Animales , Huesos/metabolismo , Envejecimiento/fisiología , Envejecimiento/metabolismo , Estrés Mecánico
11.
J Morphol ; 285(5): e21707, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38721681

RESUMEN

Using finite element analysis on the astragali of five macropodine kangaroos (extant and extinct hoppers) and three sthenurine kangaroos (extinct proposed bipedal striders) we investigate how the stresses experienced by the ankle in similarly sized kangaroos of different hypothesized/known locomotor strategy compare under different simulation scenarios, intended to represent the moment of midstance at different gaits. These tests showed a clear difference between the performance of sthenurines and macropodines with the former group experiencing lower stress in simulated bipedal strides in all species compared with hopping simulations, supporting the hypothesis that sthenurines may have utilized this gait. The Pleistocene macropodine Protemnodon also performed differently from all other species studied, showing high stresses in all simulations except for bounding. This may support the hypothesis of Protemnodon being a quadrupedal bounder.


Asunto(s)
Análisis de Elementos Finitos , Macropodidae , Animales , Macropodidae/fisiología , Macropodidae/anatomía & histología , Tobillo/fisiología , Fenómenos Biomecánicos , Marcha/fisiología , Locomoción/fisiología , Estrés Mecánico
12.
J R Soc Interface ; 21(214): 20240022, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38715321

RESUMEN

Using a three-dimensional model of cell monolayers, we study the spatial organization of active stress chains as the monolayer transitions from a solid to a liquid state. The critical exponents that characterize this transition map the isotropic stress percolation onto the two-dimensional random percolation universality class, suggesting short-range stress correlations near this transition. This mapping is achieved via two distinct, independent pathways: (i) cell-cell adhesion and (ii) active traction forces. We unify our findings by linking the nature of this transition to high-stress fluctuations, distinctly linked to each pathway. The results elevate the importance of the transmission of mechanical information in dense active matter and provide a new context for understanding the non-equilibrium statistical physics of phase transition in active systems.


Asunto(s)
Adhesión Celular , Modelos Biológicos , Adhesión Celular/fisiología , Estrés Mecánico , Transición de Fase
13.
Biomed Eng Online ; 23(1): 44, 2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38705993

RESUMEN

BACKGROUND: Osteocytes are critical mechanosensory cells in bone, and mechanically stimulated osteocytes produce exosomes that can induce osteogenesis. MicroRNAs (miRNAs) are important constituents of exosomes, and some miRNAs in osteocytes regulate osteogenic differentiation; previous studies have indicated that some differentially expressed miRNAs in mechanically strained osteocytes likely influence osteoblastic differentiation. Therefore, screening and selection of miRNAs that regulate osteogenic differentiation in exosomes of mechanically stimulated osteocytes are important. RESULTS: A mechanical tensile strain of 2500 µÎµ at 0.5 Hz 1 h per day for 3 days, elevated prostaglandin E2 (PGE2) and insulin-like growth factor-1 (IGF-1) levels and nitric oxide synthase (NOS) activity of MLO-Y4 osteocytes, and promoted osteogenic differentiation of MC3T3-E1 osteoblasts. Fourteen miRNAs differentially expressed only in MLO-Y4 osteocytes which were stimulated with mechanical tensile strain, were screened, and the miRNAs related to osteogenesis were identified. Four differentially expressed miRNAs (miR-1930-3p, miR-3110-5p, miR-3090-3p, and miR-3058-3p) were found only in mechanically strained osteocytes, and the four miRNAs, eight targeted mRNAs which were differentially expressed only in mechanically strained osteoblasts, were also identified. In addition, the mechanically strained osteocyte-derived exosomes promoted the osteoblastic differentiation of MC3T3-E1 cells in vitro, the exosomes were internalized by osteoblasts, and the up-regulated miR-3110-5p and miR-3058-3p in mechanically strained osteocytes, were both increased in the exosomes, which was verified via reverse transcription quantitative polymerase chain reaction (RT-qPCR). CONCLUSIONS: In osteocytes, a mechanical tensile strain of 2500 µÎµ at 0.5 Hz induced the fourteen differentially expressed miRNAs which probably were in exosomes of osteocytes and involved in osteogenesis. The mechanically strained osteocyte-derived exosomes which contained increased miR-3110-5p and miR-3058-3p (two of the 14 miRNAs), promoted osteoblastic differentiation.


Asunto(s)
Exosomas , MicroARNs , Osteocitos , Osteogénesis , Estrés Mecánico , Animales , Ratones , Línea Celular , Exosomas/metabolismo , Regulación de la Expresión Génica , MicroARNs/genética , MicroARNs/metabolismo , Osteoblastos/citología , Osteoblastos/metabolismo , Osteocitos/citología , Osteocitos/metabolismo , Osteogénesis/genética
14.
J Cell Biol ; 223(8)2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-38713825

RESUMEN

Whether, to what extent, and how the axons in the central nervous system (CNS) can withstand sudden mechanical impacts remain unclear. By using a microfluidic device to apply controlled transverse mechanical stress to axons, we determined the stress levels that most axons can withstand and explored their instant responses at nanoscale resolution. We found mild stress triggers a highly reversible, rapid axon beading response, driven by actomyosin-II-dependent dynamic diameter modulations. This mechanism contributes to hindering the long-range spread of stress-induced Ca2+ elevations into non-stressed neuronal regions. Through pharmacological and molecular manipulations in vitro, we found that actomyosin-II inactivation diminishes the reversible beading process, fostering progressive Ca2+ spreading and thereby increasing acute axonal degeneration in stressed axons. Conversely, upregulating actomyosin-II activity prevents the progression of initial injury, protecting stressed axons from acute degeneration both in vitro and in vivo. Our study unveils the periodic actomyosin-II in axon shafts cortex as a novel protective mechanism, shielding neurons from detrimental effects caused by mechanical stress.


Asunto(s)
Actomiosina , Axones , Estrés Mecánico , Animales , Ratones , Actomiosina/metabolismo , Axones/metabolismo , Axones/patología , Calcio/metabolismo , Células Cultivadas , Degeneración Nerviosa/patología , Ratas
15.
Jt Dis Relat Surg ; 35(2): 340-346, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38727113

RESUMEN

OBJECTIVES: The aim of this study was to investigate the effects of adding hexagonal boron nitride at four different concentrations to polymethylmethacrylate (PMMA) bone cement, which is commonly used in orthopedic surgeries, on the mechanical properties and microarchitecture of the bone cement. MATERIALS AND METHODS: The study included an unaltered control group and groups containing four different concentrations (40 g of bone cement with 0.5 g, 1 g, 1.5 g, 2 g) of hexagonal boron nitride. The samples used for mechanical tests were prepared at 20±2ºC in operating room conditions, using molds in accordance with the test standards. As a result of the tests, the pressure values at which the samples deformed were determined from the load-deformation graphs, and the megapascal (MPa) values at which the samples exhibited strength were calculated. RESULTS: The samples with 0.5 g boron added to the bone cement had significantly increased mechanical strength, particularly in the compression test. In the group where 2 g boron was added, it was noted that, compared to the other groups, the strength pressure decreased and the porosity increased. The porosity did not change particularly in the group where 0.5 g boron was added. CONCLUSION: Our study results demonstrate that adding hexagonal boron nitride (HBN) to bone cement at a low concentration (0.5 g / 40 g PPMA) significantly increases the mechanical strength in terms of MPa (compression forces) without adversely affecting porosity. However, the incorporation of HBN at higher concentrations increases porosity, thereby compromising the biomechanical properties of the bone cement, as evidenced by the negative impact on compression and four-point bending tests. Boron-based products have gained increased utilization in the medical field, and HBN is emerging as a promising chemical compound, steadily growing in significance.


Asunto(s)
Cementos para Huesos , Compuestos de Boro , Fuerza Compresiva , Ensayo de Materiales , Polimetil Metacrilato , Compuestos de Boro/química , Compuestos de Boro/farmacología , Polimetil Metacrilato/química , Cementos para Huesos/química , Ensayo de Materiales/métodos , Porosidad , Estrés Mecánico
16.
J Orthop Surg Res ; 19(1): 280, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38711149

RESUMEN

INTRODUCTION: The escalating incidence of anterior cruciate ligament (ACL) injuries, particularly among adolescents, is a pressing concern. The study of ACL biomechanics in this demographic presents challenges due to the scarcity of cadaveric specimens. This research endeavors to validate the adolescent porcine stifle joint as a fitting model for ACL studies. METHODS: We conducted experiments on 30 fresh porcine stifle knee joints. (Breed: Yorkshire, Weight: avg 90 lbs, Age Range: 2-4 months). They were stored at - 22 °C and a subsequent 24-h thaw at room temperature before being prepared for the experiment. These joints were randomly assigned to three groups. The first group served as a control and underwent only the load-to-failure test. The remaining two groups were subjected to 100 cycles, with forces of 300N and 520N, respectively. The load values of 300N and 520N correspond to three and five times the body weight (BW) of our juvenile porcine, respectively. RESULT: The 520N force demonstrated a higher strain than the 300N, indicating a direct correlation between ACL strain and augmented loads. A significant difference in load-to-failure (p = 0.014) was observed between non-cyclically loaded ACLs and those subjected to 100 cycles at 520N. Three of the ten samples in the 520N group failed before completing 100 cycles. The ruptured ACLs from these tests closely resembled adolescent ACL injuries in detachment patterns. ACL stiffness was also measured post-cyclical loading by applying force and pulling the ACL at a rate of 1 mm per sec. Moreover, ACL stiffness measurements decreased from 152.46 N/mm in the control group to 129.42 N/mm after 100 cycles at 300N and a more significant drop to 86.90 N/mm after 100 cycles at 520N. A one-way analysis of variance (ANOVA) and t-test were chosen for statistical analysis. CONCLUSIONS: The porcine stifle joint is an appropriate model for understanding ACL biomechanics in the skeletally immature demographic. The results emphasize the ligament's susceptibility to injury under high-impact loads pertinent to sports activities. The study advocates for further research into different loading scenarios and the protective role of muscle co-activation in ACL injury prevention.


Asunto(s)
Ligamento Cruzado Anterior , Rodilla de Cuadrúpedos , Soporte de Peso , Animales , Porcinos , Ligamento Cruzado Anterior/fisiología , Ligamento Cruzado Anterior/fisiopatología , Rodilla de Cuadrúpedos/fisiología , Rodilla de Cuadrúpedos/fisiopatología , Soporte de Peso/fisiología , Fenómenos Biomecánicos , Lesiones del Ligamento Cruzado Anterior/fisiopatología , Estrés Mecánico , Técnicas In Vitro
17.
Med Eng Phys ; 127: 104158, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38692761

RESUMEN

BACKGROUND: The intervertebral disc exhibits not only strain rate dependence (viscoelasticity), but also significant asymmetry under tensile and compressive loads, which is of great significance for understanding the mechanism of lumbar disc injury under physiological loads. OBJECTIVE: In this study, the strain rate sensitive and tension-compression asymmetry of the intervertebral disc were analyzed by experiments and constitutive equation. METHOD: The Sheep intervertebral disc samples were divided into three groups, in order to test the strain rate sensitive mechanical behavior, and the internal displacement as well as pressure distribution. RESULTS: The tensile stiffness is one order of magnitude smaller than the compression stiffness, and the logarithm of the elastic modulus is approximately linear with the logarithm of the strain rate, showing obvious tension-compression asymmetry and rate-related characteristics. In addition, the sensitivity to the strain rate is the same under these two loading conditions. The stress-strain curves of unloading and loading usually do not coincide, and form a Mullins effect hysteresis loop. The radial displacement distribution is opposite between the anterior and posterior region, which is consistent with the stress distribution. By introducing the damage factor into ZWT constitutive equation, the rate-dependent viscoelastic and weakening behavior of the intervertebral disc can be well described.


Asunto(s)
Fuerza Compresiva , Disco Intervertebral , Estrés Mecánico , Animales , Disco Intervertebral/fisiología , Ovinos , Fenómenos Biomecánicos , Resistencia a la Tracción , Soporte de Peso , Elasticidad
18.
J Nanobiotechnology ; 22(1): 187, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38632623

RESUMEN

Pathological conditions linked to shear stress have been identified in hematological diseases, cardiovascular diseases, and cancer. These conditions often exhibit significantly elevated shear stress levels, surpassing 1000 dyn/cm2 in severely stenotic arteries. Heightened shear stress can induce mechanical harm to endothelial cells, potentially leading to bleeding and fatal consequences. However, current technology still grapples with limitations, including inadequate flexibility in simulating bodily shear stress environments, limited range of shear stress generation, and spatial and temporal adaptability. Consequently, a comprehensive understanding of the mechanisms underlying the impact of shear stress on physiological and pathological conditions, like thrombosis, remains inadequate. To address these limitations, this study presents a microfluidic-based shear stress generation chip as a proposed solution. The chip achieves a substantial 929-fold variation in shear stress solely by adjusting the degree of constriction in branch channels after PDMS fabrication. Experiments demonstrated that a rapid increase in shear stress up to 1000 dyn/cm2 significantly detached 88.2% cells from the substrate. Long-term exposure (24 h) to shear stress levels below 8.3 dyn/cm2 did not significantly impact cell growth. Furthermore, cells exposed to shear stress levels equal to or greater than 8.3 dyn/cm2 exhibited significant alterations in aspect ratio and orientation, following a normal distribution. This microfluidic chip provides a reliable tool for investigating cellular responses to the wide-ranging shear stress existing in both physiological and pathological flow conditions.


Asunto(s)
Microfluídica , Trombosis , Humanos , Células Endoteliales , Línea Celular , Trombosis/patología , Estrés Mecánico
19.
PLoS One ; 19(4): e0297381, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38635828

RESUMEN

The new thermal insulating shotcrete is of great significance for the management of thermal damage in deep mines, and its own strength has a greater impact on the roadway insulation and safe production, so it is very necessary to study the shear strength of the new thermal insulating shotcrete under the influence of the deep hot and humid environment and the stress of mining. For the heat-insulating shotcrete, firstly, we carried out the concrete variable angle shear test under different loading rates, which concluded that the shear rate and peak shear stress showed a trend of increasing and then decreasing; as the angle increases, the different rates have a greater impact on the peak shear stress of the specimen. Secondly, the concrete variable angle shear test was carried out under the temperature and humidity cycle, which revealed that the shear strength of thermal insulated shotcrete increased firstly and then decreased with the increase of temperature at the same number of cycles. Finally, the empirical equations between the cohesive force c, the angle of internal friction ϕ and the number of warm and wet cycles n and the temperature of warm and wet cycles T are fitted with the MATLAB software respectively, and the research results provide technical references for the management of geothermal temperature in deep well projects.


Asunto(s)
Calor , Temperatura , Humedad , Estrés Mecánico
20.
PLoS One ; 19(4): e0300326, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38626003

RESUMEN

This study aimed to reduce the risk of graft occlusion by evaluating the two-phase flow of blood and LDL nanoparticles in coronary artery grafts. The study considered blood as an incompressible Newtonian fluid, with the addition of LDL nanoparticles, and the artery wall as a porous medium. Two scenarios were compared, with constant inlet velocity (CIV) and other with pulsatile inlet velocity (PIV), with LDL nanoparticles experiencing drag, wall-induced lift, and induced Saffman lift forces, or drag force only. The study also evaluated the concentration polarization of LDLs (CP of LDLs) near the walls, by considering the artery wall with and without permeation. To model LDL nanoparticles, the study randomly injected 100, 500, and 1000 nanoparticles in three release states at each time step, using different geometries. Numerical simulations were performed using COMSOL software, and the results were presented as relative collision of nanoparticles to the walls in tables, diagrams, and shear stress contours. The study found that a graft implantation angle of 15° had the most desirable conditions compared to larger angles, in terms of nanoparticle collision with surfaces and occlusion. The nanoparticle release modes behaved similarly in terms of collision with the surfaces. A difference was observed between CIV and PIV. Saffman lift and wall-induced lift forces having no effect, possibly due to the assumption of a porous artery wall and perpendicular outlet flow. In case of permeable artery walls, relative collision of particles with the graft wall was larger, suggesting the effect of CP of LDLs.


Asunto(s)
Bahías , Vasos Coronarios , Simulación por Computador , Porosidad , Modelos Cardiovasculares , Velocidad del Flujo Sanguíneo , Estrés Mecánico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA